Kontakt
Zu den Downloads

thicknessGAUGE

Sensorsystem zur präzisen Dickenmessung

thicknessGAUGE C.C

Die thicknessGAUGE C.C Sensorsysteme nutzen konfokal-chromatische Wegsensoren zur Dickenmessung. Diese Sensoren erlauben die Messung mit enormer Genauigkeit und hoher Messrate. Das innovative Messverfahren ermöglicht darüber hinaus die Messung von spiegelnden und glänzenden Oberflächen.

logo

Besonderheiten

  1. Eingesetzte Sensorik: Konfokal-chromatische Wegsensoren
  2. Messbereich Dicke: 2,5 mm
  3. Genauigkeit: ±0,4 µm
  4. Messrate: bis 10 kHz
  5. Optimal geeignet zur hochauflösenden Messung hochspiegelnder und glänzender Oberflächen
  6. Auch für transparente und semitransparente Folien
[{"activity":"DE_MEAD-2D_Buero_Mitte","address":"Wiesenstr. 29\r\n63533 Mainhausen","central":false,"comment":"B\u00fcro Mitte","companyName":"Micro-Epsilon","countries":"54","deZip":"36,60,61,63,64,68,69,90,91,92,96,97","email":"gernot.eiermann@micro-epsilon.de","emailCc":"doris.koenigseder@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 578","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1639},"internalNote":"","lName":"","map":null,"mobile":"","name":"Gernot Eiermann","phone1":"+49 8542 \/ 168 - 578","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9341,"type":null,"uid":69,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Nord","address":"Heidkoppelweg 1\r\n25474 Ellerbek","central":false,"comment":"B\u00fcro Nord","companyName":"Micro-Epsilon","countries":"54","deZip":"20,21,22,23,24,25,26,27,28,29,30,31,32,38","email":"giorgio.angelini@micro-epsilon.de","emailCc":"isabella.schramm@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 566","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1638},"internalNote":"","lName":"","map":null,"mobile":"","name":"Giorgio Angelini","phone1":"+49 8542 \/ 168 - 566","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9340,"type":null,"uid":70,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Nord-West","address":"Duisburger Str. 47\r\n46535 Dinslaken","central":false,"comment":"B\u00fcro Nord-West","companyName":"Micro-Epsilon","countries":"54","deZip":"40,41,42,44,45,46,47,48,49,50,51,52,53,58,59","email":"manfred.vanerp@micro-epsilon.de","emailCc":"astrid.bieringer@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 572","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1637},"internalNote":"","lName":"","map":null,"mobile":"","name":"Manfred van Erp","phone1":"+49 8542 \/ 168 - 572","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9339,"type":null,"uid":71,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Ost1","address":"Lessingstr. 14\r\n01465 Langebr\u00fcck","central":false,"comment":"B\u00fcro Ost 1","companyName":"Micro-Epsilon","countries":"54","deZip":"01,02,03,07,08,09,95,98","email":"olaf.gerstner@micro-epsilon.de","emailCc":"selina.krieger@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 35201 \/ 729 - 90","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1636},"internalNote":"","lName":"","map":null,"mobile":"","name":"Olaf Gerstner","phone1":"+49 35201 \/ 729 - 300","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9329,"type":null,"uid":72,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Ost2","address":"Lessingstr. 14\r\n01465 Langebr\u00fcck","central":false,"comment":"B\u00fcro Ost 2","companyName":"Micro-Epsilon","countries":"54","deZip":"04,05,06,10,11,12,13,14,15,16,17,18,19,39,99","email":"thomas.ruemmler@micro-epsilon.de","emailCc":"andrea.huber@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 35201 \/ 729 - 90","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1635},"internalNote":"","lName":"","map":null,"mobile":"","name":"Thomas R\u00fcmmler","phone1":"+49 35201 \/ 729-301","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9338,"type":null,"uid":73,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Sued-Mitte","address":"Mantelhofstrasse 12\r\n73457 Essingen\/Aalen","central":false,"comment":"B\u00fcro S\u00fcd-Mitte","companyName":"Micro-Epsilon","countries":"54","deZip":"73,74,82,86,87,88,89","email":"joachim.bauer@micro-epsilon.de","emailCc":"gertraud.moser@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 574","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1634},"internalNote":"","lName":"","map":null,"mobile":"","name":"Joachim Bauer","phone1":"+49 8542 \/ 168 - 574","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9337,"type":null,"uid":74,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Sued-Ost1","address":"K\u00f6nigbacher Str. 15\r\n94496 Ortenburg","central":false,"comment":"B\u00fcro S\u00fcdost 1","companyName":"Micro-Epsilon","countries":"54","deZip":"80,81,83,84,85,93,94","email":"klaus.brinninger@micro-epsilon.de","emailCc":"andrea.huber@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 85 42 \/ 168 - 90","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1633},"internalNote":"","lName":"","map":null,"mobile":"","name":"Klaus Brinninger","phone1":"+49 85 42 \/ 168 - 132","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9336,"type":null,"uid":75,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_Sued-West2","address":"Hinter Winterbach 10 a \r\n77794 Lautenbach","central":false,"comment":"B\u00fcro S\u00fcdwest","companyName":"Micro-Epsilon","countries":"54","deZip":"70,71,72,75,76,77,78,79","email":"udo.schwenk@micro-epsilon.de","emailCc":"doris.koenigseder@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 575","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1632},"internalNote":"","lName":"","map":null,"mobile":"","name":"Udo Schwenk","phone1":"+49 8542 \/ 168 - 575","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9335,"type":null,"uid":76,"usStates":"","website":"","worldwide":false},{"activity":"DE_MEAD-2D_Buero_West","address":"Tannenweg 9\r\n58762 Altena","central":false,"comment":"B\u00fcro West","companyName":"Micro-Epsilon","countries":"54","deZip":"33,34,35,37,54,55,56,57,65,66,67","email":"marcus.gluth@micro-epsilon.de","emailCc":"celina.kroiss@micro-epsilon.de","fName":"","fallback":false,"fallbackPagesearch":false,"fax":"+49 8542 \/ 168 - 92 503","hidePlz":false,"image":{"originalResource":{},"pid":358,"uid":1631},"internalNote":"","lName":"","map":null,"mobile":"","name":"Marcus Gluth","phone1":"+49 8542 \/ 168 - 503","phone2":"","pid":358,"products":"","regional":true,"showMail":false,"sorting":9334,"type":null,"uid":77,"usStates":"","website":"","worldwide":false}]
Kontakt
Thomas Mutzl
Zum Kontaktformular

Finden Sie Ihren Ansprechpartner

Ihre Anfrage zu: {product}
* Pflichtangaben
Wir behandeln Ihre Daten vertraulich. Bitte lesen Sie dazu unsere Datenschutzerklärung.

Präzise Dickenmessung mit konfokal-chromatischen Sensoren

Die thicknessGAUGE C.C Sensorsysteme sind betriebsfertig montiert und werkseitig kalibriert. Sie bestehen aus einem stabilen Rahmen, an dem zwei konfokal-chromatische Sensoren befestigt sind. Die Sensoren erfassen die Dicke des Messobjekts nach dem Differenzprinzip. Die konfokalen Sensoren sind montageseitig exakt aufeinander ausgerichtet und ermöglichen dadurch eine hohe Messgenauigkeit.

Über eine Linearachse wird das Sensorsystem von der Parkposition bis zur Messposition verfahren. Zur vollautomatischen Kalibrierung wird das System in die Parkposition zurückbewegt.

Die thicknessGAUGE C.C Sensorsysteme werden zur präzisen Dickenmessung von Bändern und Platten eingesetzt. Das System kann einerseits zur Festspurmessung eingesetzt werden, z.B. zur Center-Line Messung (Mittendicke) oder zur Dickenmessung am Rand. Dank der Lineareinheit kann der thicknessGAUGE auch zur traversierenden Dickenmessung bis zu 600 mm Bandbreite eingesetzt werden.

Downloads

Kataloge und Datenblätter